Standard: | IEC60598 |
---|---|
Inventory: | in Stock |
Warranty: | 1 Year |
Component: | Copper and Zinc Alloy |
Transport Package: | Protected Case |
Specification: | 0.5kg |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
1. Standards: IEC60598-1 EN60598-14.26.3
2.Test Chain is composed of copper and zinc alloy (Cu 63% Zn37%)without any surface treatment and coating , 200g/m load tensile resistance at 2.5±20%Ω.
3. It mainly used for lighting without insulation , accessible and opposite SELV part accidental short circuit protection test.
Spectifications:
1)Measuring chain resistance, to ensure that the range of 2.5 ± 20% Ω .
2)Measuring distance space of the SELV two parts, denoted as X,unit (/ cm).
3)Test chain ends hanging standard weight =15*X*g or 250g counterweight.
4)Install the thermocouple wire on proper position of the tested sample, and connecting with temperature inspecting instrument
5)Sample access 0.9~1.1 times the rated voltage of power supply.
6)Placement test chain, short-circuit test.