Warranty: | One Year |
---|---|
Electrode Pressure: | 1.0 +/- 0.05n |
The Distance Between Electrodes: | 4.0mm ± 0.01mm, Angle 60 ° ± 5 |
Electrode Voltage: | 100 ~ 600V ( |
Drops of Liquid Height: | 30 ~ 40mm Adjustable |
The Size of The Drops: | 44 to 55 Drops |
Customization: |
---|
Suppliers with verified business licenses
Electrode Materials | The electrode caput of brass-platinum |
Electrode Distance | 4.0mm±0.1mm,60±5°angle |
Test Voltage | 100~600V adjustable, displayed value: r.m.s |
the electrode pressure |
1.0 ± 0.05N |
drops of liquid height | 30 ~ 40mm adjustable |
the size of the drops |
44 to 55 drops / 1cm3 Adjustable |
drops Time | 30s ± 5s, |
the number of drops | 0 to 9999 times adjustable |
the leakage judge | loop current greater than 0.5A and maintain the 2 seconds the relay to cut off the current, indicating that the sample failed |
the test process | automatic control of test procedures, independent ventilation |
reference standards | IEC60112-2003, GB/T4207-2003, GB4706.1-2005 |
the studio volume | >0.5m³, black interior |
outer dimensions | 1000mm wide x 650mm deep x 1300mm high |
Power Supply | 800VA ,220V, 48-60Hz |