Customization: | Available |
---|---|
Installation Type: | Duct Type, Soil |
Sensing Type: | Thermocouple, Resistive |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Compared | MS20 | MEC20 |
Soil Moisture Measurement | Range:0-50%,0-100% Resolution:0-50%:0.03%,50-100%:1% Accuracy:0-50%:2%,50-100%:3% |
Range:0-50%,0-100% Resolution:0-50%:0.03%,50-100%:1% Accuracy:0-50%:2%,50-100%:3% |
Temperature Measurement | Range: -40~80ºC, Resolution:0.1ºC, Accuracy:±0.5ºC | Range: -40~80ºC, Resolution:0.1ºC, Accuracy:±0.5ºC |
EC Measurement | None | Range: 0-5000us/cm, 10000us/cm, 20000us/cm Resolution: 0-10000us/cm, 10us/cm; 100000-20000us/cm, 50us/cm Accuracy: 0-10000us/cm, ±3%; 10000-20000us/cm, ±5% EC temperature compensation: 0-50ºC |
MS20 | Code | Comments |
Code 1: Product Series |
MS20 | MS20 Soil Moisture, Temperature Sensor |
Code 2: Measuring Parameters |
A B |
Soil Moisture & Temperature Soil Moisture |
Code 3: Soil Moisture Range |
A B |
0-100% 0-50% |
Code 4: Output Interface |
A B C D E F G |
Analog Voltage 0-2V Analog Current 4-20mA RS485,Modbus-RTU RS485,Modbus-RTU & Analog Voltage 0-2V RS485,Modbus-RTU & Analog Current 4-20mA SDI-12 Customize |
Code 5: Power Supply |
A B C D E |
3.6-30V DC (not applicable for 4-20mA output) 12-30V DC 2.7-16V DC (not applicable for 4-20mA output) Customize 2.0-5.5V DC (not applicable for 4-20mA output) |
Code 6: Cable Length |
002 XXX |
2 meters Customize, XXX is required cable length(Unit: meter) |
Ordering Code Example: MS20 Sensor with Soil Moisture & Temperature parameters, Soil Moisture Range 100%, Output Interface RS485 Modbus RTU, Power Supply 3.6-30V DC, Cable Length 5 meters. Ordering Code is : MS20 - A A C A 005 |
MEC20 | Code | Comments |
Code 1: Product Series |
MEC20 | MEC20 Soil Moisture, EC, Temperature Sensor |
Code 2: Measuring Parameters |
A B |
Soil Moisture & Temperature & EC (only for RS485 output) Soil Moisture & EC |
Code 3: Soil Moisture Range |
A B |
0-50% 0-100% |
Code 4: EC Range |
A B C D |
0-5000us/cm 0-10000us/cm 0-20000us/cm Customize |
Code 5: Power Supply |
A B C D E |
3.6-30V DC (not applicable for 4-20mA output) 12-30V DC 2.7-16V DC (not applicable for 4-20mA output) Customize 2.0-5.5V DC (not applicable for 4-20mA output) |
Code 6: Output Interface |
A B C D E F G |
Analog Voltage 0-2V Analog Current 4-20mA RS485,Modbus-RTU RS485,Modbus-RTU & Analog Voltage 0-2V RS485,Modbus-RTU & Analog Current 4-20mA SDI-12 Customize |
Code 7: Cable Length |
002 XXX |
2 meters Customize, XXX is required cable length(Unit: meter) |
Ordering Code Example: MEC20 Sensor with Soil Moisture & EC & Temperature parameters, Soil Moisture Range 100%, Soil EC Range 20000us/cm, Power Supply 3.6-30V DC, Output Interface RS485, Modbus-RTU, Cable Length 5 meters. Ordering Code is : MEC20 - A B C A C 005 |