power Load Cabinet
Resistance inductance load cabinet
Universal Lab Power Load Cabinet Tank Test
1).Suitable standard
IEC60335, IEC60884, IEC60669, IEC61058-1
2)Scope and application
Overview The load cabinet is designed according to the technical and customer requirements of the national standard IEC, GB and VDE, and is suitable for electrical materials and other samples requiring high current load output life test.
3)The main Technical Parameters
1. Use power: with ground single phase AC208V ± 10% / 60Hz;
2. Digital output voltage value, current value, power, power factor, meter accuracy: 0.5 level;
3. The built-in load is the resistor chip group:
4. Current output mode: R and L are two choices;
5. Adjustable power factor regulator (reactor) capacity is 5 kVA; (optional)
6. Single output current is: ≤40A;
7. The output voltage regulator has a capacity of 18 kVA, and the voltage AC: 5 ~ 280V is manually adjustable (optional).
8. Power factor can be adjusted to: 0.3 ~ 0.999 (optional)
9. Current recognition time range: 0.5 ~ 99.99 times can be preset
10. The maximum power consumption of this machine: 20kVA 11.Power:AC208V / 60Hz Single Phase
4).Control Panel Description