Battery Thermal Abuse Test Chamber

Product Details
Customization: Available
After-sales Service: Good
Warranty: 1 Year
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (21)
  • Battery Thermal Abuse Test Chamber
  • Battery Thermal Abuse Test Chamber
  • Battery Thermal Abuse Test Chamber
  • Battery Thermal Abuse Test Chamber
  • Battery Thermal Abuse Test Chamber
  • Battery Thermal Abuse Test Chamber
Find Similar Products
  • Overview
  • Specification
Overview

Basic Info.

Model NO.
BND-BTAT
Type
All Types of Batteries
Test Region
Temperature
Application
All Types of Batteries
Customized
Customized
Inner Box Material
SUS #304 Stainless Steel
Outer Box Material
Cold Rolled Steel Plate
Thermal Insulation Material
Glass Wool
Temperature Range
Rt ~ 200 ° C
Transport Package
Wooden Box
Specification
500 mm (W) * 600 mm (H) * 500 mm (D) (support cust
Trademark
SZBONAD
Origin
China
Production Capacity
10 Pieces/Month

Product Description

BONAD IEC 62133 Battery Thermal Abuse Test Chamber - High-Temperature Endurance Testing for Lithium Batteries
BONAD's Battery Thermal Abuse Test Chamber (High-Temperature Endurance Test Chamber) is a cutting-edge 2-in-1 solution designed for rapid heating tests on lithium-ion cells, modules, and battery packs. This multipurpose equipment evaluates resistance to extreme temperature spikes and conducts molded case stress tests, ensuring safety compliance and performance validation. With a temperature range of RT+10°C to 200°C and a non-linear heating rate of (5±2)°C/min, it delivers precise, reliable results while optimizing lab efficiency.
Key Applications
1. Thermal Abuse Testing:
Tests fully charged cells/modules at (130±2)°C (30-min hold) to verify explosion/fire resistance.
2. Molded Case Stress Testing:
Exposes battery modules to (70±2)°C for 7 hours to check for case deformation or component exposure.
3. Compliance Testing:
Validates batteries against IEC 62133, UL1642, IEC 62619, IEC 62660, and other global standards.
Compliance Standards
IEC 62133
UL 1642
IEC 62619
IEC 62660
Design & Features
Safety & Durability
Explosion-Proof Design: Rear explosion-proof port + safety chains.
Robust Construction: Cold-rolled steel shell, stainless steel interior, and thermal insulation filling.
Ventilation System: Dual-side vents prevent combustible gas buildup; forced air circulation ensures rapid temperature recovery.
Precision & Control
Temperature Sensor: PT-100 sensor for linearity, stability, and uniformity.
Smart Control: PID microcomputer + touch screen for real-time PV/SV monitoring.
Heating Efficiency: Forced-air circulation via electric heater and wind wheel minimizes energy loss.
User Convenience
Visibility: Thickened tempered glass window + internal lighting.
Mobility: 4 universal wheels for easy transport.
Protections: No-fuse switch, over-temperature alarm, and auto-cutoff.
Testing Procedures
1. Thermal Abuse Test:
Heat sample to (130±2)°C at (5±2)°C/min → Hold 30 mins → Cool to RT.
Pass Criteria: No explosion/fire.
2. Molded Case Stress Test:
Maintain sample at (70±2)°C for 7 hours → Cool to RT.
Pass Criteria: No case distortion exposing internal components.
Why Choose BONAD?
Cost-Effective: Dual-function design (thermal abuse + stress testing) saves space and budget.
Customizable: Chamber dimensions tailored to your sample capacity.
Safety-First: Explosion-proof engineering meets rigorous global standards.
Global Compliance: Pre-validated for IEC, UL, and UN testing protocols.
Specification
Model
BND-BTAT
Inner Box Material
SUS#304 stainless steel
Outer Box Material
Cold rolled steel plate
Thermal InsulationMaterial
Glass wool
Inner Box Size
500mm (W) *600mm (H) *500 mm(D)(support customization)
Temperature Range
RT ~200 ° C
TemperatureDisplay Accuracy
±0.1 °C
Temperature Uniformity
± 2° C
Temperature Accuracy
±0.5 °C
Heating Rate
(5±2) ° C/min(non-linear no-load, adjustable heating rate)
Observation Window
Tempered glass
Smoke Exhaust Design
Equipped with exhaust fan and anexternal ductto connect to high power exhaust system in lab
Explosion-proof Vent Design
Located at the backof the equipment. After the pressure relief is complete, the pressure relief vent is able to automatically.return to original position.
Temperature Cycle
Forced convection with a blower fan
Power supply
AC220V±10%,50Hz,18Aor 110 V ±10%
Customize Your Test Chamber!
Provide your sample details (size, capacity) for a tailored solution. Contact BONAD today for competitive pricing and technical support!
Battery Thermal Abuse Test Chamber
Battery Thermal Abuse Test Chamber
Battery Thermal Abuse Test Chamber
Battery Thermal Abuse Test Chamber
Battery Thermal Abuse Test Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier