Customization: | Available |
---|---|
After-sales Service: | Good |
Power Supply: | 110V 220V 380V, 110V 220V 380V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | BND-HAST-250 | BND-HAST-350 | BND-HAST-250D | BND-HAST-350D | BND-HAST-250M | BND-HAST-350M | ||
Inner size(cm) | 25*D35 | 30*D45 | 40*D55 | 50*D60 | 25*D35 | 30*D45 | ||
External size(cm) | W56*H65*D105 | W*66*H105*D125 | W76*H115*D135 | W86*H135*D145 | W56*H65*D105 | W66*H105*D125 | ||
Temperature range | 105ºC~132ºC | 105ºC~142.9ºC | 105ºC~155ºC | |||||
Pressure range | Table pressure +0.2~2.0kg/cm2 | Table pressure +0.2~3.0kg/cm2 | Table pressure +0.2~3.5kg/cm2 | |||||
Humidity range | 65%~100RH(adjustable) | |||||||
Controller | HAST-6890 model ,dedicated controller,chinese and english display,with USB connector,R-232C Interface data curve download | |||||||
Resolution | Temperature:0.1ºC , humidity :0.1%RH ,pressure:0.1kg/cm2 | |||||||
Temperature and humidity fluctuation range | Unsaturated control:0.1ºC / ±2.5%RH , Wet saturation control:±0.5ºC / 100%RH | |||||||
Bias terminal | none | Standard 8 pcs (8-55pcs can be choose), AC and DC 125V 1A | ||||||
Air pressurization | External gas source | External gas source | External gas source | |||||
Pressurized time | About 45 min | About 50 min | About 55 min | |||||
Cycle mode | Forced convection circulation | |||||||
Internal materials | SUS316 stainless steel | |||||||
External materials | Cold - rolled steel plate anti - static spraying | |||||||
Insulation Materials | Glass wool | |||||||
Pressure vessel | Heater, humidifier, temperature sensor, sample signal terminal, convection fan, convection fan motor, anti-overheat / dry test terminal | |||||||
Sample rack | Sample separator(2layer),Customized sample racks | |||||||
Control panel | Controller, power key, process indicator, alarm light, mechanical pressure gauge, manual emergency pressure cutting, USB interface, R-485 interface | |||||||
Communication function | RS-485 | |||||||
Water supply | Automatic water supply | |||||||
Safety protection | The whole process to detect over-temperature over-voltage protection, the first phase of the instrument internal ultra-high temperature protection, the second phase of the instrument internal humidifier water protection, high pressure protection, water tank alarm,The second phase of the humidifier limit temperature protection, the second stage of ultra-high voltage protection, the third stage of emergency pressure relief, manual pressure relief, automatic pressure relief |
Company Profile :Our Advantages :
Certifications :Factory Introduction :
Plant Warehouse :
Cooperative Customers & Brands:
Customer Reviews :Product Packaging :